AC Micro Milli Volt Meter-401
Systronics AC Mcro/Milli Volt Meter 401 is a solid state precision instrument, measurng AC Voltages from 10õV to 500 V r.m.s. over a frequency range of 1Hz to 3MHz. Designed for easy operation, the instrument gives direct reading of voltage or dB on diital display.
The unit uses a stable, high gain AC amplifier, which delivers essentially, a hum free, low noise micro phony signal output. Operated on mains, this test instrument is sturdily constructed and is enclosed in an elegan metallic cabinet with a pair of rugged, plastic moulded, dual position stands.
Technical Specfications
Range
|
Voltage: 2 mV to 2000 V Full Scale in 7 Decadc Range, (Max. 500 V)
|
dB: 60 dB to + 60 dB in steps of 20 dB (Reference: 0 dB corresponds to 1 mW across 600é) |
|
Measuring Rane
|
Voltage: 10 µV to 500 V
|
|
dB: 95 dB to + 56 dB
|
|
Measurement Accuracy (AT 1KHz)
|
Voltage Scale: +- 1% of Full Sclae +- 1 diit dB Sclae: +- 0.5 dB
|
|
Frequency Response
|
(At 0.0 dB; 0.775 V) +- 0.5 dB from 4 Hz to 1 MHz & +- 3.0 dB from 1 Hz to 3 MHz
|
|
Display
|
Seven segment LED; 3.1/2 Digit
|
|
Input mpedance
|
For 2 mV & 20 mV Ranges: 5 Mé // 50 pF (Approx.)
|
Above 20 mV ranges: 5 Mé // 20 pF (Approx.)
|
|
Input Noise
|
For 2 mV Range: 5 õV + 5 Least Counts 20 mV & Above: 5 Least Counts
|
|
Amplifier
|
The output is phase inverted, undistorted replica of input in mV correspondin to displayed figure irrespective of range with maximum 200 mV at full scale
|
|
Maximum Safe Input
|
For 2 mV & 20 mV Range: 250 V DC + 100 V AC upto 20 KHz
Above 20 mV Range: 750 V peak AC + DC
|
|
Power Supply
|
230 V, 50 Hz +- 10%
|
|
Dimension
|
65 x 215 x 210 mm
|
|
Weight
|
@ 1.75 Kg.
|
|